<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-26 13-13-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 47 dBuV YLESUOMI
Pilot RDS Phase Difference
7.0 kHz 3.4 kHz 73 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 17269 5,5417
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,4 dBr 4,47 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 2 (Affairs) 1 0 1 1 13:13, 26.01.2026
RT
"EPPU "
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6205, 6201, 6202, 6207
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 5,5417 Acquired: 2026/01/26 13.12.14 Total samples: 17269 Equivalent time: 0:14:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,7 dBr MIN: 2,4 dBr AVE: 4,47 dBr % above 12,2 dBr: 0,0 Last value: 4,0 dBr (2026/01/26 13.12.14) 12.58 13.00 13.02 13.04 13.06 13.08 13.10 13.12 0 2 4 6 Pm [dBr]